All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.

 |  |
Features for TopPette
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
Features for multi-channel TopPette
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
 |
 |
Calibration Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation. Â We will support and help you to achieve consistently excellent results. Â |
 |
Â
Single-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.1-2.5μL | 0.05μL | 2.5μL | 2.50% | 0.0625 | 2.00% | 0.05 | |||||
1.25μL | 3.00% | 0.0375 | 3.00% | 0.0375 | |||||||
0.25μL | 12.00% | 0.03 | 6.00% | 0.015 | |||||||
0.5-10μL | 0.1μL | 10μL | 1.00% | 0.1 | 0.80% | 0.08 | |||||
5μL | 1.50% | 0.075 | 1.50% | 0.075 | |||||||
1μL | 2.50% | 0.025 | 1.50% | 0.015 | |||||||
2-20μL | 0.5μL | 20μL | 0.90% | 0.18 | 0.40% | 0.08 | |||||
10μL | 1.20% | 0.12 | 1.00% | 0.1 | |||||||
2μL | 3.00% | 0.06 | 2.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 0.60% | 0.3 | 0.30% | 0.15 | |||||
25μL | 0.90% | 0.225 | 0.60% | 0.15 | |||||||
5μL | 2.00% | 0.1 | 2.00% | 0.1 | |||||||
10-100μL | 1μL | 100μL | 0.80% | 0.8 | 0.15% | 0.15 | |||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
10μL | 3.00% | 0.3 | 1.50% | 0.15 | |||||||
20-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
20μL | 3.00% | 0.6 | 1.00% | 0.2 | |||||||
50-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
100-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
100μL | 2.00% | 2 | 0.70% | 0.7 | |||||||
200-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
200μL | 0.90% | 1.8 | 0.30% | 0.6 | |||||||
1000-5000μL | 50μL | 5000μL | 0.50% | 25 | 0.15% | 7.5 | |||||
2500μL | 0.60% | 15 | 0.30% | 7.5 | |||||||
1000μL | 0.70% | 7 | 0.30% | 3 | |||||||
2-10mL | 0.1mL | 10mL | 0.60% | 60 | 0.20% | 20 | |||||
5mL | 1.20% | 60 | 0.30% | 15 | |||||||
2mL | 3.00% | 60 | 0.60% | 12 | |||||||
8-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
12-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
Fixed Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
5μL | - | 5μL | 1.3% | 0.065 | 1.2% | 0.06 | |||||
10μL | - | 10μL | 0.8% | 0.08 | 0.8% | 0.08 | |||||
20μL | - | 20μL | 0.6% | 0.12 | 0.5% | 0.1 | |||||
25μL | - | 25μL | 0.5% | 0.125 | 0.3% | 0.075 | |||||
50μL | - | 50μL | 0.5% | 0.25 | 0.3% | 0.15 | |||||
100μL | - | 100μL | 0.5% | 0.5 | 0.3% | 0.3 | |||||
200μL | - | 200μL | 0.4% | 0.8 | 0.2% | 0.4 | |||||
250μL | -- | 250μL | 0.4% | 1.0 | 0.2% | 0.5 | |||||
500μL | - | 500μL | 0.3% | 1.5 | 0.2% | 1.0 | |||||
1000μL | - | 1000μL | 0.3% | 3.0 | 0.2% | 2.0 | |||||
2000μL | - | 2000μL | 0.3% | 6.0 | 0.15% | 3.0 | |||||
5000μL | - | 5000μL | 0.3% | 15 | 0.15% | 7.5 |


All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.

 |  |
Features for TopPette
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
Features for multi-channel TopPette
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
 |
 |
Calibration Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation. Â We will support and help you to achieve consistently excellent results. Â |
 |
Â
Single-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.1-2.5μL | 0.05μL | 2.5μL | 2.50% | 0.0625 | 2.00% | 0.05 | |||||
1.25μL | 3.00% | 0.0375 | 3.00% | 0.0375 | |||||||
0.25μL | 12.00% | 0.03 | 6.00% | 0.015 | |||||||
0.5-10μL | 0.1μL | 10μL | 1.00% | 0.1 | 0.80% | 0.08 | |||||
5μL | 1.50% | 0.075 | 1.50% | 0.075 | |||||||
1μL | 2.50% | 0.025 | 1.50% | 0.015 | |||||||
2-20μL | 0.5μL | 20μL | 0.90% | 0.18 | 0.40% | 0.08 | |||||
10μL | 1.20% | 0.12 | 1.00% | 0.1 | |||||||
2μL | 3.00% | 0.06 | 2.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 0.60% | 0.3 | 0.30% | 0.15 | |||||
25μL | 0.90% | 0.225 | 0.60% | 0.15 | |||||||
5μL | 2.00% | 0.1 | 2.00% | 0.1 | |||||||
10-100μL | 1μL | 100μL | 0.80% | 0.8 | 0.15% | 0.15 | |||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
10μL | 3.00% | 0.3 | 1.50% | 0.15 | |||||||
20-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
20μL | 3.00% | 0.6 | 1.00% | 0.2 | |||||||
50-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
100-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
100μL | 2.00% | 2 | 0.70% | 0.7 | |||||||
200-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
200μL | 0.90% | 1.8 | 0.30% | 0.6 | |||||||
1000-5000μL | 50μL | 5000μL | 0.50% | 25 | 0.15% | 7.5 | |||||
2500μL | 0.60% | 15 | 0.30% | 7.5 | |||||||
1000μL | 0.70% | 7 | 0.30% | 3 | |||||||
2-10mL | 0.1mL | 10mL | 0.60% | 60 | 0.20% | 20 | |||||
5mL | 1.20% | 60 | 0.30% | 15 | |||||||
2mL | 3.00% | 60 | 0.60% | 12 | |||||||
8-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
12-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
Fixed Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
5μL | - | 5μL | 1.3% | 0.065 | 1.2% | 0.06 | |||||
10μL | - | 10μL | 0.8% | 0.08 | 0.8% | 0.08 | |||||
20μL | - | 20μL | 0.6% | 0.12 | 0.5% | 0.1 | |||||
25μL | - | 25μL | 0.5% | 0.125 | 0.3% | 0.075 | |||||
50μL | - | 50μL | 0.5% | 0.25 | 0.3% | 0.15 | |||||
100μL | - | 100μL | 0.5% | 0.5 | 0.3% | 0.3 | |||||
200μL | - | 200μL | 0.4% | 0.8 | 0.2% | 0.4 | |||||
250μL | -- | 250μL | 0.4% | 1.0 | 0.2% | 0.5 | |||||
500μL | - | 500μL | 0.3% | 1.5 | 0.2% | 1.0 | |||||
1000μL | - | 1000μL | 0.3% | 3.0 | 0.2% | 2.0 | |||||
2000μL | - | 2000μL | 0.3% | 6.0 | 0.15% | 3.0 | |||||
5000μL | - | 5000μL | 0.3% | 15 | 0.15% | 7.5 |


Main introduction of Lowbed semi trailer
Lowbed semi trailer, also known as low bed trailer, lowboy trailer, low bed trailer. The main plane of the cargo bed of the trailer is low, which ensures the smoothness of transportation, and is suitable for carrying various mechanical equipment, large objects, highway construction equipment, large tanks and various steel materials, etc.
Lowboy Trailer for sale in Philippines
Common Types of Low Flatbed Trailers
1. Gooseneck Lowbed Semi Trailer
The general structure of the gooseneck lowbed semi trailer adopts a concave beam frame (or well type), that is, the front section of the frame is the gooseneck, the middle section is the cargo platform (the lowest part of the frame), and the rear end is the wheel frame (including wheels).
And according to the type of rear-mounted ladder, it is divided into mechanical ladder gooseneck lowbed trailer and hydraulic gooseneck low bed trailer.
2.Rgn Trailer ( Removable gooseneck trailer)
RGN trailer is a detachable gooseneck trailer, some equipment mounted on the trailer gooseneck can be manually removed or attached so that the mechanical equipment can be unloaded from the front of the trailer. This trailer is mainly suitable for large construction machinery.
RGN Trailer For Sale
3. Other low bed trailers
In addition to the above two common lowbed trailers, there are also high and low high and low flatbed trailers, axis low flatbed trailers, wobbly low flatbed trailers, tank low flatbed trailers and other options, which can be customized by customers according to their needs.
Structural advantages of Chengda low bed trailer:
Production process of the low bed trailer
1. Considering the force of the low-bed trailer, the main beam of the chengda trailer is made of Q345B high-strength manganese steel, and the side beam is made of Q235 manganese steel to ensure the strength and toughness of the car body.
2. The low bed trailer adopts high quality body/BPW, FUWA or China certified axles, the quality is guaranteed.
3. Low bed trailer gooseneck structure manufacturing, service life up to 15 years
4. American-style suspension thickened lifting lugs with suspension 90X13X10 pieces, good shock absorption effect, strong and durable, easy to maintain
5. Hydraulic low-bed trailers and mechanical low-bed trailers use a weighted climbing ladder, tripod support, small slope, strong load-bearing and not easy to deform.
6. After sandblasting and rust removal on the frame of the low-bed trailer, it is sprayed with the well-known Pentium polyurethane paint in China, which is more anti-corrosion and rust-proof.
3 Axles 60T Low Bed Semi Trailer
Basic configuration of 3 Axles 60T Low Bed Semi Trailer
Dimension and Weight
Overall Dimension(mm)
13000x3000x1650mm
Working Deck Dimension(mm)
9000x3000x1350mm
Platform thickness(mm)
4mm
Main Beam
[H"main beam design,Q345B carbon steel,
the height of the beam is 500 mm,
upper plate is 16mm,down plate is 18mm, middle plate is 10 mm.
Payload
60,000kg
Running System
Axle
13Ton, ZY brand optional FUWA brand
Tire
1100R20, 12 pcs Taitong brand
Suspension system
Common Mechanical Suspension
Emergency relay valve
Wabco relay valve
Tool box
1pcs, One crank and one shaft head wrench
Our service
1. Chengda can recommend the number of trailer axles according to the type and load of the goods to be transported by the customer, so as to provide the customer with the most economical solution.
2. Support ODM & OEM customization, the best solution is provided by professional technical design team, free logo printing.
3. The trailer assembly has been strictly tested.
4. The electrical circuit is 100% inspected before leaving the factory, and the braking performance is good.
5. Use the most suitable tires according to the customer's road conditions, such as:
Kenya 315/80R22.5.
Ethiopia Djibouti 1200R20.
Tanzania and Malawi Single 385/65R22.5 or Twin 1200R22.5.
Lowbed Semi Trailer,Heavy Low Bed Semi Trailer,4 Axles Low Bed Truck Trailer,Fission Gooseneck Lowbed Trailer
Shandong Chengda Auto Sales Co., Ltd. , https://www.chengdasemitrailer.com